Back to Companypage
Business Logo
 
  • Konzern
    • About us
    • Management
    • Press
    • Events
    • Employees
    • Careers
    • Sponsoring
  • Business Units
    • Analytical Instrumentation
    • Life Science
    • Optics
  • Produkte
    • Products from A to Z
  • Investor | Media Relations
    • Key Figures
    • Share
    • Financial Reports
    • Annual Document
    • Corporate Governance
    • Ad Hoc Announcements
    • Director’s Dealings
    • Annual General Meeting
    • Financial Calendar
    • Press Releases
Analytical Instrumentation
  • Philosophy
  • Company Profile
  • References
  • History
  • Products
    • Atomic Spectrometry
    • Molecular Spectroscopy
    • Sum Parameters (TOC/TN | TOX)
      • TOC | TN Analysis
      • AOX | TOX | TX Analysis
      • Automation | Accessories
    • Elemental Analysis
    • Antioxidants | Free radicals
  • Service | Support
  • Events
  • Press Center
  • Contact

Sign in

  • AJ International |
  • Languages
    • English
    • Deutsch
    • Español
    • Français
    • Русский
    • 日本語
 

back to Sum Parameters

TOC | TN Analysis

multi N/C® series – The right analyzer for every application

The multi N/C® series is the powerful family of instruments with a convincing overall concept for the fully automatic and simultaneous analysis of total organic carbon (TOC) and total nitrogen (TN) from every sample.

  • multi N/C 3100
  • multi N/C 2100
  • multi N/C UV HS
  • multi N/C pharma HS
space

multi N/C 3100

Analyzer with a particularly wide measuring range

Analyzer for determination of bound carbon contents (TIC/TOC, TC, NPOC, POC) and/or of total nitrogen (TNb) in aqueous and solid samples with innovative VITA technology.

 

At a glance:

  • Effective sample digestion
  • High productivity
  • Multi Channel-Non Dispersive Infrared Detector (MC-NDIR)
  • Signal optimization (VITA – retention time coupled integration in TOC analysis)
  • Self Check System (SCS)
  • High Temperature Combustion (HTC) for TOC in solids
  • FDA-compliant software

multi N/C® 3100 – Thermocatalytic digestion, NDIR detection for TOC analysis. TN analysis by either electrochemical detector (CHD) or chemiluminescence (CLD). Sample feed is by flow injection. Automatic correction of flow variations through VITA technology. Upgradeable with HT 1300 for solids analysis, and an autosampler for liquid samples with 64 or 116 positions. This TOC/TN analyzer can be used for most diverse samples from all fields of application. It stands out by a particularly wide measuring range. The analyzer is available as a PC version or as a stand-alone version with a high-performance touch screen.

Upgradable with:

  • HT 1300 (high-temperature solids combustion system, suited for the direct determination of TOC or TC)
  • TIC solids module (direct determination of TIC in solids)
  • APG 64 (xyz autosampler – either with automatic dilution)
  • ChD (TNb determination with electrochemical solid state detector)
  • CLD (TNb determination with chemoluminescence detector)
 
space

multi N/C 2100

Robust system for simultaneous determination of TOC and TNb

Analyzer for determination of carbon contents (TIC/TOC, TC, NPOC, POC) and/or of total nitrogen (TNb) in aqueous and solid samples.

 

multi N/C® 2100

Thermocatalytic digestion, NDIR detection for TOC analysis. TN analysis by either electrochemical detector (CHD) or chemiluminescence (CLD). Sample feed is by direct injection. The analyzer is equipped with a double furnace to enable analysis of aqueous and solid samples without an additional combustion furnace.


At a glance:

  • Effective sample digestion
  • High productivity
  • Double furnace
  • Multi Channel-Non Dispersive Infrared Detector (MC-NDIR)
  • High Temperature Combustion (HTC) for TOC in solids
  • FDA-compliant software


multi N/C® 2100 S

Thermocatalytic digestion, NDIR detection for TOC analysis. TN analysis by either electrochemical detector (CHD) or chemoluminescence (CLD). Sample feed is by direct injection. Automatic correction of flow variations through VITA technology. This TOC/TN analyzer can be used for most diverse samples from all fields of application. The analyzer is equipped with a double furnace to enable analysis of aqueous and solid samples without an additional combustion furnace. The analyzer is available as a PC or a stand-alone version.


At a glance:

  • Effective sample digestion
  • High productivity
  • Double furnace
  • Multi Channel-Non Dispersive Infrared Detector (MC-NDIR)
  • Signal optimization (VITA – retention time coupled integration in TOC analysis)
  • Self Check System (SCS)
  • High Temperature Combustion (HTC) for TOC in solids
  • FDA-compliant software

 

Upgradable with:

  • APG 60 (xyz autosampler)
  • HT 1300 (high-temperature solids combustion system, suited for the direct determination of TOC or TC)
  • TIC solids module (direct determination of TIC in solids)
  • Double furnace (analysis of samples without additional combustion furnace)
  • ChD (TNb determination with electrochemical solid state detector)
  • CLD (TNb determination with chemoluminescence detector)
 
space

multi N/C UV HS

Analyzer with wet-chemical UV/persulfate digestion

Analyzer for determination of bound carbon contents (TIC/TOC, TC, NPOC, POC) in aqueous and solid samples with innovative VITA technology – wet-chemical digestion for aqueous samples in the UV reactor – singularly high sensitivity.

 

At a glance:

  • Effective sample digestion
  • High productivity
  • Wide-range infrared detector (NDIR)
  • High Temperature Combustion (HTC) for TOC in solids
  • FDA-compliant software

multi N/C® UV HS – Wet-chemical UV/persulfate digestion, NDIR detection for versatile TOC analysis in a particularly wide concentration range.

This analyzer can be used both for trace-level TOC measurements (e.g., water samples in the pharmaceutical industry or semiconductior industry) and for TOC measurements in the range of high or very high concentrations. The TOC analyzer is available with complete validation (IQ/OQ).

Upgradable with:

  • APG 49 (xyz autosampler – for liquid samples, for up to 49 vials)
  • HT 1300 (high-temperature solids combustion system, suited for the direct determination of TOC or TC)
 
space

multi N/C pharma HS

Analyzer for trace-level TOC/TN analysis

Analyzer for determination of bound carbon contents (TIC/TOC, TC, NPOC, POC) and/or of total nitrogen (TNb) in aqueous samples with innovative VITA technology.

 

At a glance:

  • Effective sample digestion
  • High productivity
  • Multi Channel-Non Dispersive Infrared Detector (MC-NDIR)
  • Signal optimization (VITA – retention time coupled integration in TOC analysis)
  • Self Check System (SCS)
  • FDA-compliant software

multi N/C® pharma HS – Thermocatalytic digestion, highly sensitive NDIR detection for trace-level TOC analysis. Sample feed is by flow injection. Automatic correction of flow variations through VITA technology.

This TOC analyzer is specially suitable for TOC analyses of ultrapure waters, such as water samples in pharmaceutical industry. The TOC analyzer is available with complete validation (IQ/OQ).

Upgradable with:

  • APG 49 (xyz autosampler – for liquid samples, for up 49 vials)
  • Swab test module (high temperature solid sample module)
  • CLD (TNb determination with chemiluminescence detector)
 

top

 
AJ Blomesystem GmbH | AJ Cybertron GmbH | AJ eBiochip GmbH | AJ IDC GmbH | AJ Innuscreen GmbH
AJ Roboscreen GmbH | AJZ Engineering GmbH | Biometra GmbH | CyBio AG
Analytik Jena AG | Contact | Imprint | Conditions of Use | Privacy Policy | Sitemap